SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2023-3587, Submission # Submission-2023-3805, UID # 47212
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 07/05/2023 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Tank Integrity (Compliance Component #2) - Failing to protect groundwater Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
Yes |
: | septic tank |
Verification method(s): | Examined construction records Examined empty (pumped) tank(s) |
Comments/Explanation: | The owner declined to expose the maintenance hole cover & signed the form for pumping through the inspection pipe. The tank was pumped & backflushed through the inspection pipe. Performed a visual inspection & lowered a light & camera into the empty tank - no outlet baffle & the tank appears to be leaking at the seam. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 10/24/1973 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
A. Bottom of distribution media: | 3.2 Decimal Feet |
B. Periodically saturated soil/bedrock: | 4.5 Decimal Feet |
C. System separation: | 1.3 Decimal Feet |
D. Required compliance separation: | 2 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | tomtrooien@aol.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #9265 (07/05/2023)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 07/05/2023 4:53 PM $47 Flat Fee |
$45.00 | x 1 | $45.00 |
Grand Total | |||
Total | $45.00 | ||
Payment 07/05/2023 | $45.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Tom Trooien - 07/05/2023 4:54 PM 3d75f29e9dcaa3c235d3a2bfee53d7ee aea4f649aedaae9a32b094fa44328f0b | |
#1 Compliance Inspection Accepted | Sarah Borrell - 08/08/2023 9:39 AM 53b5d3b700982f0f95d5e138629caadd 853e98e6b5ecd114567cb658ef7626d1 |
Inspection has been approved. All signatures have been obtained.
Text: | 6 month extension - 2024 |
File(s): |
Text: | 11/6 (SB) new owner, Daniel Rice, 651-216-6349, left a voicemail. His contractor cannot get to install prior to winter/freeze up and would like an extension. I called him back and asked him to email a request to me. |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Noncompliant |
Certificate of Compliance: |
Letter of Non-Compliance: |