Compliance Inspection Compliance Inspection Compliance Inspection # CI-2023-3590, Submission # Submission-2023-3808, UID # 47221
Status: Compliance Inspection Accepted
 

System Status

System status on date: 07/07/2023 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
120302144000311900 102ND ST N, CITY OF GRANT11900102NDSTNSTILLWATERCITY OF GRANT55082HOOPS ELIZABETH M & ROBERT L11RED HAWK RIDGE1990
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined empty (pumped) tank(s)
Comments/Explanation:
The tank was at normal operating level, then was pumped & backflushed. Lowered a camera in the empty tank - bottom, walls, cover, baffles, riser & maintenance hole cover ok

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 07/03/1990

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 1.9 Decimal Feet
B. Periodically saturated soil/bedrock: 4.5 Decimal Feet
C. System separation: 2.6 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #9267 (07/07/2023)

Charge Cost Quantity Total
Non-Taxable
added 07/07/2023 7:59 AM

$47 Flat Fee

$45.00 x 1 $45.00
Grand Total
Total $45.00
Payment 07/07/2023$45.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 07/07/2023 7:59 AM
54b34ade9a2f4a8e9ea0399d2bf2ea77
4b5b088d37593c5014eed7da003f7015
 
#1 Compliance Inspection AcceptedSarah Borrell - 08/08/2023 9:47 AM
2b5957e7ccc5e44c05e84570bb69f02a
4a6919da51f668f7dbef33024bb893b6
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Certificate of Compliance Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Compliant
      Certificate of Compliance:
        Letter of Non-Compliance: