SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2023-3766, Submission # Submission-2023-3826, UID # 47477
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 07/10/2023 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined empty (pumped) tank(s) |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 03/07/1988 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
Yes |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
A. Bottom of distribution media: | 97 Decimal Feet |
B. Periodically saturated soil/bedrock: | 93.3 Decimal Feet |
C. System separation: | 3.7 Decimal Feet |
D. Required compliance separation: | 2 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | alex.pepin@tenthirtyenvironmental.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #9341 (07/27/2023)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 07/27/2023 10:11 AM $47 Flat Fee |
$45.00 | x 1 | $45.00 |
Grand Total | |||
Total | $45.00 | ||
Payment 07/27/2023 | $45.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Alex Pepin - 07/27/2023 10:11 AM b72fdf3a4d6499b77795304841537e19 693d9f15c17e019656c8d21b1cc520c4 | |
#1 Compliance Inspection Accepted | Sarah Borrell - 12/22/2023 2:26 PM dce4d032a05bc8f006eb11860570b8f9 d28d45f4f932c04cdcd53b91e305d71c |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | 12/22/23 (SB) as we've been contacted by a licensed designer to design/install a new system for the property that is adequate for current and proposed uses. We determined that sending a letter was not necessary at this time. * DRAFT (never sent) - The Certificate of Compliance establishes that the SSTS meets the minimum standards for an existing system. However, as described in the inspection report, the system is not adequately sized for the current use and will need proper upgrades for the expansion. The exact scope of improvements will be determined by a licensed design business based off the proposed sewage generated from existing and proposed uses, and the specifics of the site. |
File(s): |
Compliance Letter Type: | Certificate of Compliance | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | No | Compliant/Non-Compliant: | Compliant |
Certificate of Compliance: |
Letter of Non-Compliance: |