Compliance Inspection Compliance Inspection Compliance Inspection # CI-2023-3770, Submission # Submission-2023-3997, UID # 50076
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 11/13/2023 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Other Compliance Conditions (Compliance Component #3) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Visual inspection of the area |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Tank(s) were not emptied because the manhole access did not have a riser extending the tank access to the surface. Additionally, the tank was 8' deep. Unable to determine if the 10.5' deep inspection was for a dropbox or cesspool. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
Unknown |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | See attached soil boring log and site plan for location of tank, cesspool or dropbox, and boring. |
A. Bottom of distribution media: | 10.5 Decimal Feet |
B. Periodically saturated soil/bedrock: | 3.5 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 2 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | See attached soil boring log and site plan for location of tank, cesspool or dropbox, and boring. |
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): | Jesse Kloeppner |
Inspector Email Address: | jesse@ksd-mn.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #9778 (11/18/2023)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 11/18/2023 4:29 PM $47 Flat Fee |
$45.00 | x 1 | $45.00 |
Grand Total | |||
Total | $45.00 | ||
Payment 11/18/2023 | $45.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Jesse J. Kloeppner - 11/18/2023 4:29 PM 89813b97ddecc66fdf8c8b7e143cdf0f d97eb8b9b854d9d66151260102dc87ed | |
#1 Compliance Inspection Accepted | Sarah Borrell - 12/27/2023 1:08 PM 372e08adb227d1a25cbe04465787013b 4bf48ad726411f1c8c74055b9b62fc0d |
Inspection has been approved. All signatures have been obtained.
Text: | Tank(s) noncompliant as was not pumped/inspected |
File(s): |
Text: | 3/7 (SB) spoke w/ a realtor on SSTS as they thought system had been connected to city sewer. I provided info on system abandonment. they also had well questions which I referred to MDH and provided sealing assistance info. 1/29 (SB) I spoke w/ Title agent representing seller. No escrow or forms required by PHE at time of transfer. Dept. will work with whoever to bring system into compliance. 1/16 (SB) I took a call from a prospective buyer, wanted to know what was wrong with SSTS. I informed her system was inspected by a third party, licensed inspector, and found to be noncompliant and failing to protect groundwater with possible cesspool(s) and would require complete replacement. The buyer expressed no longer having interest in the property. |
File(s): |
|
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Noncompliant |
Certificate of Compliance: |
Letter of Non-Compliance: |