Compliance Inspection Compliance Inspection Compliance Inspection # CI-2024-3781, Submission # Submission-2023-4010, UID # 50454
Status: System Replaced
 

System Status

System status on date: 11/20/2023 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
020312034000414598 OLD GUSLANDER TRL N, TOWN OF MAY14598OLD GUSLANDERTRLNMARINE ON ST CROIXTOWN OF MAY55047GROOTAERS JAN-LODEWIJK1993
Owner's representative:
Name:
Jan Loedwijk-Grootaers
Phone:
(612518 - 7965
Email:
janlodewijkgrootaers@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)
Comments/Explanation:
See attached report.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined Tank Integrity Form (Attach)
Comments/Explanation:
See attached report.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 10/20/1992

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
System previously failed for lack of separation.
A. Bottom of distribution media: 97.2 Decimal Feet
B. Periodically saturated soil/bedrock: 100 Decimal Feet
C. System separation: -2.8 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Zierke Soil Testing, LLCL119651-249-134628587 Jeffrey Ave Chisago City, MN 55013NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: benzierke@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #9805 (12/05/2023)

Charge Cost Quantity Total
Non-Taxable
added 12/05/2023 7:39 PM

$47 Flat Fee

$45.00 x 1 $45.00
Grand Total
Total $45.00
Payment 12/05/2023$45.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBenjamin J. Zierke - 12/05/2023 7:40 PM
15682b09c8d479158d08c9da9519256f
c08ac6df596aeadc88e78e99c2888e58
 
#1 Compliance Inspection AcceptedSarah Borrell - 01/08/2024 9:43 AM
42d25d2184f768072ab04bfcf28900ed
ae09a9b9af45736e830be61f070a3a86
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    Note, noncompliant report filed in 2015
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance: