Compliance Inspection Compliance Inspection Compliance Inspection # CI-2024-3958, Submission # Submission-2024-4271, UID # 54407
Status: Compliance Inspection Accepted
 

System Status

System status on date: 08/06/2024 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
03029212400039455 55TH ST N, CITY OF LAKE ELMO945555THSTNLAKE ELMOCITY OF LAKE ELMO55042HUGHES JOHN R & CHARLENE11JUDITH MARY MANOR1998
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined empty (pumped) tank(s)
Comments/Explanation:
Precast combo septic tank was at its normal operating level, then was pumped through the manholes. Lowered a light & camera into the empty tank - bottom, walls, cover, baffles, risers & manhole covers ok

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 08/06/1998

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 3.3 Decimal Feet
B. Periodically saturated soil/bedrock: 6.8 Decimal Feet
C. System separation: 3.5 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #10517 (08/06/2024)

Charge Cost Quantity Total
Non-Taxable
added 08/06/2024 7:09 PM

$47 Flat Fee

$46.00 x 1 $46.00
Grand Total
Total $46.00
Payment 08/06/2024$46.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 08/06/2024 7:09 PM
3f3009eb8f1ab51ff49aa0d70c6a3c8b
a209d843a1c44b65999019482df9fbcf
 
#1 Compliance Inspection AcceptedSarah Borrell - 08/16/2024 2:09 PM
1a951422fd4c883f6fb6dff1e1d2ab21
2a7eeef23db0950d836038f524d5e7d0
 
Inspection has been approved. All signatures have been obtained.
Text:
Any additional for bedroom should be properly sized.
File(s):
    Text:
    8/19/24 - Lake Elmo building inspector called me, he said he just needed something stating the existing SSTS was okay or not. I left him a voicemail and said I was confused if it was bedroom addition or not, which would require upgrades, but the HO thought this was just finishing the basement and it was already planned for a 4 bedroom when it was installed. I told John he could call me if he had questions on the sizing otherwise the COC was issued by All State Septic Services
    8/16/24 - 651-263-9740, talked with property owner, he's finishing the basement. City does not have records of the home but they moved it and he recalls the SSTS being properly sized for a bedroom in the basement. HE said total bedrooms would be 4, I told him the septic tank size is shy and should be increased. Recommended to contact his Inspector to help with the size of drainfield.
    File(s):
      Compliance Letter Type: Certificate of Compliance Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Compliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by