SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2024-4064, Submission # Submission-2024-4314, UID # 55529
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 09/18/2024 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Excessive ponding in soil system/D-boxes |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined construction records Examined empty (pumped) tank(s) |
Comments/Explanation: | The tanks were at normal operating level, then were pumped through the manholes. Lowered a light & camera into the empty tanks - bottoms, walls, covers, baffles, risers & manhole covers ok. The tanks & drainfield have some roots in them, which may affect their longevity. The high water alarm was operational at the time of inspection. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 05/16/2007 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
A. Bottom of distribution media: | 2.4 Decimal Feet |
B. Periodically saturated soil/bedrock: | 5.5 Decimal Feet |
C. System separation: | 3.1 Decimal Feet |
D. Required compliance separation: | 3 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | tomtrooien@aol.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #10658 (09/18/2024)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 09/18/2024 2:53 PM $47 Flat Fee |
$46.00 | x 1 | $46.00 |
Grand Total | |||
Total | $46.00 | ||
Payment 09/18/2024 | $46.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Tom Trooien - 09/18/2024 2:53 PM 8bad7a3563b762394d1a09accaf14e1e 4d2aa07c00964ee6a843b96d4a05e1f5 | |
#1 Compliance Inspection Accepted | Sarah Borrell - 11/21/2024 3:20 PM dee6d7a1ccbe29c4b788e323d0ce5de6 6a532f19ddbf869dc761942b1820c33c |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Certificate of Compliance | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Compliant |
Certificate of Compliance: |
Letter of Non-Compliance: |