Compliance Inspection Compliance Inspection Submission # Submission-2024-4358, UID # 56063
Status: Pending Review
 

System Status

System status on date: 09/25/2024 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Other Compliance Conditions (Compliance Component #3) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
320272132000111973 GREY CLOUD TRL S, CITY OF COTTAGE GROVE11973GREY CLOUDTRLSCOTTAGE GROVECITY OF COTTAGE GROVE55016LACHAPELLE NANETTE M1980
Owner's representative:
Name:
Nanette
Phone:
(952905 - 6953
Email:
sssepticsolutions@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)
Comments/Explanation:
Cabin not being used.  System needs to be properly abandoned.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Could not located tank but the owner through she remembered one being there. The system needs to be properly abandoned.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Other (See Comments/Explanation)
Comments/Explanation:
Pipe coming out of the cabin from the bathroom.  Could not locate the tank.  Systems needs to be abandoned by Washington County code.
A. Bottom of distribution media: 0 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
SS Septic Solutions LLCL4137651-343-911714845 113th St S Hastings, MN 55033NoYesNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: sssepticsolutions@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #10727 (10/16/2024)

Charge Cost Quantity Total
Non-Taxable
added 10/16/2024 5:26 PM

$47 Flat Fee

$46.00 x 1 $46.00
Grand Total
Total $46.00
Payment 10/16/2024$46.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantShelley L. Schlomka - 01/06/2025 6:08 PM
efdbc6bf16c70b9ed8ad61056ffcee94
546008893693dee6b260f47152919e22
 
#1 Compliance Inspection Accepted 
You do not have the necessary rights for this signature
Inspection has been approved. All signatures have been obtained.
Text:
STRAIGHT PIPE
File(s):
Text:
12/26 - I returned report to Shelley - communication below
12/23/24 - clarifying address property is for and also needs to change to ITPS for straight up
File(s):
Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
Was the letter sent? Compliant/Non-Compliant:
Certificate of Compliance:
    Letter of Non-Compliance:
      Powered by