SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0713, Submission # Submission-2016-0515, UID # 6210
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 11/16/2016 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Opened Dropboxes, owner cleared sand from #3 and reset inspection tube |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined construction records Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Visual inspection of full tanks. Effluent levels were correct, baffles were in place |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
A. Bottom of distribution media: | 30 Decimal Feet |
B. Periodically saturated soil/bedrock: | 72 Decimal Feet |
C. System separation: | 42 Decimal Feet |
D. Required compliance separation: | 36 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | 2- 1000gal. septic tanks, drain to 3 trenches, 45' 70',80' |
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | jana@steinbrechercompanies.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #1608 (11/21/2016)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 11/21/2016 2:40 PM $40 Flat Fee |
$40.00 | x 1 | $40.00 |
Grand Total | |||
Total | $40.00 | ||
Payment 06/02/2017 | $40.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Steinbrecher Companies - 06/02/2017 11:38 AM - witnessed by Kati Hallermann 36b123dba289d0c6c4ed31e8417f191d 1644ae0a4b9b310fcc800841cfcb65a4 | |
#1 Compliance Inspection Accepted | Kati Hallermann - 06/02/2017 11:38 AM f1a6b2e380e55f26051807985b01a55e 4c059b1292176e0b4a722ed149dbf031 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | Invoiced: 5.25.2017 |
File(s): |
Compliance Letter Type: | Who's signature should be on the letter? | Permit number to reference in "No Replace" letter: | |||
Was the letter sent? | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |