SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0554, Submission # Submission-2017-0590, UID # 7486
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 01/03/2017 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Tank Integrity (Compliance Component #2) - Failing to protect groundwater Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Homeowner testimony (See Comments/Explanation) |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
Yes |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom Examined construction records |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 01/15/2004 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
Yes |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | B1 0-11 Sandy Clay Topsoil... 10yr 4/4 11-26 Sandy Clay Loam... 10yr 5/6 26-66 Med Sand... 7.5yr 5/4 B2 0-32 Loam... 10yr 3/2 32-66 Silty Clay Loam 10yr 6/2 redox @ 37" 7.5yr 6/8 |
A. Bottom of distribution media: | 36 Decimal Feet |
B. Periodically saturated soil/bedrock: | 37 Decimal Feet |
C. System separation: | 42 Decimal Feet |
D. Required compliance separation: | 36 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | See report for full report: "Old" Tanks & drainfield plus "new" 1500 & 1350 septic tanks with 1350 pump tank & 25x60 Pres bed. The plumbing from the kitchen & Laundry room in the east side of the house is still connected to the "old' septic system which is failing due to lack of separation. This plumbing should be disconnected from the old system & connected to the 'new' system that was installed in 2004. The old system should then be properly abandoned. See report for full report. |
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | tomtrooien@aol.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #1786 (02/01/2017)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 02/01/2017 8:44 AM $40 Flat Fee |
$40.00 | x 1 | $40.00 |
Grand Total | |||
Total | $40.00 | ||
Payment 02/01/2017 | $40.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Tom Trooien- All State Septic Services - 02/01/2017 8:45 AM - witnessed by Kati Hallermann bc494fd6abf33bf852a5668cc133664f 5b99c3ca4e1cfb3d41ca90cdd237e7f7 | |
#1 Compliance Inspection Accepted | Christopher W. LeClair REHS - 02/06/2017 10:10 AM 65a91e9b92da0bc70262905c19710415 c0aac9d701476b7fc31d2c537fec3150 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Who's signature should be on the letter? | Permit number to reference in "No Replace" letter: | |||
Was the letter sent? | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |