SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0577, Submission # Submission-2017-0628, UID # 7931
Status: Compliance Inspection Accepted
Status: Compliance Inspection Accepted
System Status
System status on date: | 02/09/2017 | System Status: | Compliant |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Excessive ponding in soil system/D-boxes |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom Examined construction records |
Comments/Explanation: | Lowered Camera into tanks, baffles OK. Effluent in both tanks is at normal operating level. Recommend securing manhole covers on both tanks. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | Yes |
Date of installation: | 12/01/1992 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
Yes |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | B1 0-6 topsoil... 10yr 3/3 6-20 snayd silt loam... 10yr 4/4 20-28 laomy sand... 7/5yr 4/3 28-66 fine/med sand... 10yr 5/4 |
A. Bottom of distribution media: | 36 Decimal Feet |
B. Periodically saturated soil/bedrock: | 0 Decimal Feet |
C. System separation: | 30 Decimal Feet |
D. Required compliance separation: | 24 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | 1,250 gallon septic tank & 1000gallon pump tank lifting to 1,200 SF rock trench, gravity drainfield. The existing home on this parcel was destroyed by fire. This inspection was performed to verify the existing septic system is OK to reuse. When the home is rebuilt, a new sewer line is needed to connect the septic tank to the new h9ome. Also needed is a new high water alarm. Need to verify the pump is operational & run separate circuits for the pump & alarm. |
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | tomtrooien@aol.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #1841 (03/08/2017)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 03/08/2017 10:54 AM $40 Flat Fee |
$40.00 | x 1 | $40.00 |
Grand Total | |||
Total | $40.00 | ||
Payment 03/08/2017 | $40.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Tom Trooien - 03/08/2017 10:54 AM - witnessed by Kati Hallermann 2a085a010d445b3d1b11572ee79e1e1d 1a9633d03289277203eb1b9f63160350 | |
#1 Compliance Inspection Accepted | Kati Hallermann - 03/08/2017 10:54 AM 3982779dcf597aadadd629f992323003 ee0f43220ab6c750e47f486b5fea4d8b |
Inspection has been approved. All signatures have been obtained.