Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0577, Submission # Submission-2017-0628, UID # 7931
Status: Compliance Inspection Accepted
 

System Status

System status on date: 02/09/2017 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
080292023000913211 48TH ST N, TOWN OF BAYTOWN1321148THSTNSTILLWATERTOWN OF BAYTOWN55082CRDD TRS12SHORES OF LAKE MCDONALD2017
Owner's representative:
Name:
Bob Moser
Phone:
(651483 - 5132
Email:
bobmoser@moserhomesinc.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records
Comments/Explanation:
Lowered Camera into tanks, baffles OK. Effluent in both tanks is at normal operating level. Recommend securing manhole covers on both tanks.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 12/01/1992

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
B1 0-6 topsoil... 10yr 3/3
6-20 snayd silt loam... 10yr 4/4
20-28 laomy sand... 7/5yr 4/3
28-66 fine/med sand... 10yr 5/4
A. Bottom of distribution media: 36 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 30 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
1,250 gallon septic tank & 1000gallon pump tank lifting to 1,200 SF rock trench, gravity drainfield. The existing home on this parcel was destroyed by fire. This inspection was performed to verify the existing septic system is OK to reuse. When the home is rebuilt, a new sewer line is needed to connect the septic tank to the new h9ome. Also needed is a new high water alarm. Need to verify the pump is operational & run separate circuits for the pump & alarm.
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #1841 (03/08/2017)

Charge Cost Quantity Total
Non-Taxable
added 03/08/2017 10:54 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 03/08/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 03/08/2017 10:54 AM - witnessed by Kati Hallermann
2a085a010d445b3d1b11572ee79e1e1d
1a9633d03289277203eb1b9f63160350
 
#1 Compliance Inspection AcceptedKati Hallermann - 03/08/2017 10:54 AM
3982779dcf597aadadd629f992323003
ee0f43220ab6c750e47f486b5fea4d8b
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance: