Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0786, Submission # Submission-2017-0783, UID # 8886
Status: System Replaced
 

System Status

System status on date: 05/30/2017 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
050322043001423263 LOFTON CT N, CITY OF SCANDIA23263LOFTONCTNSCANDIACITY OF SCANDIA55073NEWBY KENNY M & CODY A CHAMBERLAIN8SANDGREN ADD1958
Owner's representative:
Name:
Judy Giesler
Phone:
(651433 - 4437
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
See Report
System is non protective of groundwater for other
conditions as determined by the inspector:
No
Explain:
See Report

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
See Report
A. Bottom of distribution media: 0 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 0 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See Report
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #2159 (06/09/2017)

Charge Cost Quantity Total
Non-Taxable
added 06/09/2017 11:46 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 06/23/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 06/09/2017 11:47 AM
a6ac6cd0fe9d07f49241a4f9ed7e764e
e0c9d32249151c5ca65a0a90cca5f665
 
#1 Compliance Inspection AcceptedAlex Pepin - 07/14/2017 7:38 AM
73e99c02a670feb63a973eb02e9ab1f0
359040ada7fe0702c6195e5591109a14
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    Going out on 7/13/17 to verify soils - AP
    
    Soil Log 7/13/2017 by Alex Pepin and Pete Ganzel--> 0-4 inches 10 YR 3/2 sandy loam blocky moderate; 4-42 inches 10 YR 4/4 sandy clay loam blocky and firm.... iron concretions and carbonates present in sandy clay loam profile; redox (10 YR 6/2 with 7.5 YR 4/4 present at 38 inches)... Separation of 20 inches with bottom of system at 18 inches as designed.... does not meet separation and is in line with what compliance inspector is seeing.... Order to replace with thought of mound over old system.... have 20 inches below old system and 1 foot above.... need 1 ft sand base mound....
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Alex Pepin Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by