Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0745, Submission # Submission-2017-0813, UID # 9117
Status: Compliance Inspection Accepted
 

System Status

System status on date: 05/16/2017 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
020282022000216036 QUALITY CT S, CITY OF LAKELAND16036QUALITYCTSLAKELANDCITY OF LAKELAND55043PATTERSON PAUL D9PINE GROVE ADD1972
Owner's representative:
Name:
Tom Trooien
Phone:
(612594 - 4496
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 07/22/1991

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
B1-
0-15 sandy topsoil... 10yr 3/3
15-46 med sand... 7.5yr 4/3
46-72 med/course sand... 7.5yr 4/4
A. Bottom of distribution media: 42 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 30 Decimal Feet
D. Required compliance separation: 24 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
1000 gallon septic tank and 590SF of gravity rock trench drainfield
5/22/1985 10100gallon septic tank & 390SF of drainfield installed to replace original cesspool/drywell system.  7/22/1991- 200SF of drainfield added for addition.    10/- tank pumped, baffle replaced and new riser installed
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tom.trooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #2228 (06/22/2017)

Charge Cost Quantity Total
Non-Taxable
added 06/22/2017 11:41 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 06/22/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 06/22/2017 11:42 AM - witnessed by Kati Hallermann
a828a0791f175f2ce4be7a50a71918fe
5a79bca4f0077997a012193c631be8ae
 
#1 Compliance Inspection AcceptedKati Hallermann - 06/22/2017 11:42 AM
2f039b36c0f9ac6579801f2efc8b81d9
5f94998d1fb5b568a453d629962357c3
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by