Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0827, Submission # Submission-2017-0878, UID # 9444
Status: System Replaced
 

System Status

System status on date: 07/17/2017 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
07029202400114736 MCDONALD DRIVE PL N, TOWN OF BAYTOWN4736MCDONALD DRIVEPLNSTILLWATERTOWN OF BAYTOWN55082GOULET BRADLEY JLR & BRIDGET191CLOVERDALE FARM1994
Owner's representative:
Name:
Taylor Pass (Keller Williams)
Phone:
(651439 - 4000
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See Report

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
See Report
System is non protective of groundwater for other
conditions as determined by the inspector:
No
Explain:
See Report

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Other (See Comments/Explanation)
Comments/Explanation:
See Report
A. Bottom of distribution media: 0 Decimal Feet
B. Periodically saturated soil/bedrock: 0 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 0 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
See Report
taylorhousley@kw.com
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #2362 (07/21/2017)

Charge Cost Quantity Total
Non-Taxable
added 07/21/2017 8:44 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 07/21/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 07/21/2017 8:44 AM
4c8df7425d658664c9557543f1850f8d
e47c6769e6eec10cc8813681fed6fd81
 
#1 Compliance Inspection AcceptedChristopher W. LeClair REHS - 07/25/2017 8:38 AM
151e7bdd4a273e776c6b35572a944ff4
531afc6a5d60f059d0823fdff2bee393
 
Inspection has been approved. All signatures have been obtained.
Text:
Conducted soil review on 7-24-2017.  Depth of of system bottom 36".  Noted redox in the silt layer from 42-52".  At 52" the soil texture was coarse sand.  Therefore, the redox noted from 42-52" is a perched water table condition, not regional water table.  There was no redoximporphic features noted from 52-72".  System has separation.  CWL
File(s):
Text:
Conducted soil review on 7-24-2017.  Depth of of system bottom 36".  Noted redox in the silt layer from 42-52".  At 52" the soil texture was coarse sand.  Therefore, the redox noted from 42-52" is a perched water table condition, not regional water table.  There was no redoximporphic features noted from 52-72".  System has separation.  CWL

6/22/22 (SB) see attached communication. Midwest called on doing compliance inspection and design work. Asked if they needed to do a compliance inspection if they planned to replace the system and put money in escrow. Responded that they needed the compliance inspection prior to transfer unless there was a valid COC on file. He said they plan to close on 7/21 so would likely not have time to replace the system.
File(s):
Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
Was the letter sent? Compliant/Non-Compliant:
Letter of Non-Compliance: