SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2016-0044, Submission # Submission-2016-0025, UID # 959
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 12/02/2015 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
Yes |
Explain: | Redoxification present at 42" Bottom or drainfield at 49" Soil saturation at 48"-50" Separation standard not met |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | Redox 42" Saturated soil 48" |
A. Bottom of distribution media: | 4 Decimal Feet |
B. Periodically saturated soil/bedrock: | 4 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 2 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | 1 Septic tank and drainfield |
Attach Files: |
|
Certification
Inspector: |
|
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #475 (01/07/2016)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 01/07/2016 9:39 AM $40 Flat Fee |
$40.00 | x 1 | $40.00 |
Grand Total | |||
Total | $40.00 | ||
Payment 03/29/2016 | $40.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | 3bikmC720 - 01/07/2016 9:48 AM - witnessed by Christopher W. LeClair REHS bcaf2c73a881cf77a720e6902f9c40f2 499ea6d116bd63527bbadaa7c79265d5 | |
#1 Compliance Inspection Accepted | Christopher W. LeClair REHS - 03/16/2016 9:15 AM 4d6513fb045c540802cbcd041fda89d2 f61fffd7c293f112082368dfbf07d0fc |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Who's signature should be on the letter? | Permit number to reference in "No Replace" letter: | |||
Was the letter sent? | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |
|