Compliance Inspection Compliance Inspection Compliance Inspection # CI-2018-1274, Submission # Submission-2018-1323, UID # 15382
Status: System Replaced
 

System Status

System status on date: 05/09/2018 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Tank Integrity (Compliance Component #2) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
360272131001811600 LAYTON AVE S, CITY OF COTTAGE GROVE11600LAYTONAVESHASTINGSCITY OF COTTAGE GROVE55033HORVATH LAURIE M & COREY M21PINE COULEE 2ND ADD1969
Property Owner's Mailing Address
(if different than property address):
23620 Lillehei Avenue
Hampton MN 55031
Owner's representative:
Name:
Bob Freiermuth
Phone:
(657437 - 5566
Email:
bfsbob1@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
Yes
Sewage tank(s) leak below their
designed operating depth:
Yes
Verification method(s):
Probed tank(s) bottom
Observed liquid level below operating depth

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
Explain:
no Manhole covers  pipe's up
System is non protective of groundwater for other
conditions as determined by the inspector:
Yes
Explain:
cesspool's

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
1-22" 10yr4/4 topsoil
22-35" 10yr5/6 sandy loam
35-65" 10yr 6/6 med sand
A. Bottom of distribution media: .22 Decimal Feet
B. Periodically saturated soil/bedrock: .65 Decimal Feet
C. System separation: .43 Decimal Feet
D. Required compliance separation: .36 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
property need's new system
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Bob Freiermuth Sanitation LLCL492651-437-556623620 Lillehei Ave Hampton, MN 55031NoNoNoNoNo
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): Bob Freiermuth
Inspector Email Address: bfsbob1@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #3335 (06/03/2018)

Charge Cost Quantity Total
Non-Taxable
added 06/03/2018 11:53 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 06/03/2018$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBob Freiermuth - 06/03/2018 11:54 AM
5162d1cb3bb032db8d4cb2db209e32e9
8f3542b0e298c77289c56ffe8a2aff32
 
#1 Compliance Inspection AcceptedTyler Dale - 06/13/2018 2:43 PM
08efdbc349574e9e9001016a52040c71
6bb68226218567a73151fb4f69a0d4a4
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Cesspool Who's signature should be on the letter? Tyler Dale Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by