Compliance Inspection Compliance Inspection Compliance Inspection # CI-2018-1526, Submission # Submission-2018-1582, UID # 18901
Status: System Replaced
 

System Status

System status on date: 11/26/2018 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
10030211100039989 110TH ST N, CITY OF GRANT9989110THSTNSTILLWATERCITY OF GRANT55082FU XIAOYUN1991
Owner's representative:
Name:
Aaron Rosell- Keller Williams
Phone:
(651705 - 6312
Email:
noemail@noemail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Comments/Explanation:
Nothing else observed at the time of inspection. Home is vacant

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined construction records
Comments/Explanation:
Tank pumped deferred until drainfield is replaced at which time tanks should be pumped and checked for size & integrity per installation records tanks are precast tank approx. 1250gal septic tank & 1000gal lift tank. tanks may be reused if deemed good but is subjected to new drainfield design layout & sizing factors

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
drainfield does not meet compliance and must be replaced to bring into compliance per installation records fill soils were brought in to install septic system which do not comply with or meet compliance criteria- see county for detailed records of fill soils.
A. Bottom of distribution media: 30 Decimal Feet
B. Periodically saturated soil/bedrock: 30 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 36 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Comments or recommendations:
pressurized trenches in fill soils with septic tank & lift tank.
Drainfield does not have the vertical separation required for the proper treatment of wastewater, and therefore does not meet MPCA Ch 7080 compliance criteria Tank pumping deferred until upgrade-see sec #2 tanks
Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Mac's Sewer ServicesL1476651-462-151034918 Falcon Ave N North Branch, MN 55056NoNoNoNoNo
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: macsewer12@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #3984 (11/29/2018)

Charge Cost Quantity Total
Non-Taxable
added 11/29/2018 2:36 PM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 12/06/2018$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantMichael McElhatton - 11/29/2018 2:37 PM - witnessed by Kati Hallermann
04e97980c30101fdb9e8dbd65563a504
f46984b42987bd525df9abfe0548e07b
 
#1 Compliance Inspection AcceptedTyler Dale - 12/03/2018 4:28 PM
426ee319895e101fcefe5c3e25dd79a2
9baa78f131e564c1ca2ffeb225ca867a
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Tyler Dale Permit number to reference in "No Replace" letter:
    Was the letter sent? Compliant/Non-Compliant:
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by