SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2018-1526, Submission # Submission-2018-1582, UID # 18901
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 11/26/2018 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home |
Comments/Explanation: | Nothing else observed at the time of inspection. Home is vacant |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined construction records |
Comments/Explanation: | Tank pumped deferred until drainfield is replaced at which time tanks should be pumped and checked for size & integrity per installation records tanks are precast tank approx. 1250gal septic tank & 1000gal lift tank. tanks may be reused if deemed good but is subjected to new drainfield design layout & sizing factors |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | drainfield does not meet compliance and must be replaced to bring into compliance per installation records fill soils were brought in to install septic system which do not comply with or meet compliance criteria- see county for detailed records of fill soils. |
A. Bottom of distribution media: | 30 Decimal Feet |
B. Periodically saturated soil/bedrock: | 30 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 36 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Comments or recommendations: | pressurized trenches in fill soils with septic tank & lift tank. Drainfield does not have the vertical separation required for the proper treatment of wastewater, and therefore does not meet MPCA Ch 7080 compliance criteria Tank pumping deferred until upgrade-see sec #2 tanks |
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | macsewer12@gmail.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #3984 (11/29/2018)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 11/29/2018 2:36 PM $40 Flat Fee |
$40.00 | x 1 | $40.00 |
Grand Total | |||
Total | $40.00 | ||
Payment 12/06/2018 | $40.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Michael McElhatton - 11/29/2018 2:37 PM - witnessed by Kati Hallermann 04e97980c30101fdb9e8dbd65563a504 f46984b42987bd525df9abfe0548e07b | |
#1 Compliance Inspection Accepted | Tyler Dale - 12/03/2018 4:28 PM 426ee319895e101fcefe5c3e25dd79a2 9baa78f131e564c1ca2ffeb225ca867a |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Tyler Dale | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |