Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1936, Submission # Submission-2019-2002, UID # 23851
Status: System Replaced
 

System Status

System status on date: 09/16/2019 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
260322023000419580 ORWELL AVE N, CITY OF SCANDIA19580ORWELLAVENMARINE ON ST CROIXCITY OF SCANDIA55047SELNER KATHRYN J & MICHAEL J42MERRYWOOD 2ND ADD2022
Owner's representative:
Name:
Merrywood LLC
Phone:
(123456 - 7890
Email:
noemail@email.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes
Comments/Explanation:
There is presently no house on the property.

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom
Examined construction records
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Lowered underwater camera into tank - baffles and tank walls OK.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
Comments/Explanation:
Septic Installed: 1992

Soil observation
0-18 inches: 10YR 2/2 Loamy Fine Sand
18-33 inches: 7.5YR 4/3 Loamy Fine Sand
33-40 inches: 7.5YR 3/4 Medium Sand
40-51 inches:7.5YR 3/4 Medium Sand With Loamy Fine Sand Layers And
7.5YR 5/8 & Few 5YR 3/4 Redox
A. Bottom of distribution media: 4 Decimal Feet
B. Periodically saturated soil/bedrock: 3.3 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Midwest Sewer ServicesL2896651-492-75506616 Indian Wells Trail Grant, MN 55110YesYesYesYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: brian@midwestsoiltesting.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #4857 (09/18/2019)

Charge Cost Quantity Total
Non-Taxable
added 09/20/2019 9:08 AM

$41 Flat Fee

$41.00 x 1 $41.00
Grand Total
Total $41.00
Payment 09/20/2019$41.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBrian Humpal - 09/20/2019 9:08 AM
53b94eddc274d0cbaa07194896412285
7bbb4ba4e335206f09099626eff6d390
 
#1 Compliance Inspection AcceptedPaul O'Neel - 10/08/2019 1:29 PM
67bd1474b5e8493328e010beb713a1f9
616a1b938242964f362d628505a2cf6a
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    10/04/2019: I question the location of soil boring in relation to the STA.
    Emailed inspector 10-07-19. PMO
    10-07-2019: Spoke with Chris from Inspect MN & Midwest Soil Testing at 12p.m. Chris will make changes to inspection report to reflect reason SSTS failed. There is no house on property. Unknown as to what happen to structure (fire, torn down). PMO
    10-08-2019: Brian Humpal emailed revised compliance inspection report. Added to file. PMO
    File(s):
    Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Paul O'Neel Permit number to reference in "No Replace" letter:
    Was the letter sent? Yes Compliant/Non-Compliant:
    Certificate of Compliance:
      Letter of Non-Compliance:
        Powered by