SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2019-1936, Submission # Submission-2019-2002, UID # 23851
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 09/16/2019 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for surface outlet Searched for seeping in yard/backup into home Excessive ponding in soil system/D-boxes |
Comments/Explanation: | There is presently no house on the property. |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Probed tank(s) bottom Examined construction records Other methods not listed (See Comments/Explanation) |
Comments/Explanation: | Lowered underwater camera into tank - baffles and tank walls OK. |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
No |
Date of Install
Date of install known: | No |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | Yes |
Drainfield has at least a three-foot vertical separation distance from periodically saturated soil or bedrock.: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
Comments/Explanation: | Septic Installed: 1992 Soil observation 0-18 inches: 10YR 2/2 Loamy Fine Sand 18-33 inches: 7.5YR 4/3 Loamy Fine Sand 33-40 inches: 7.5YR 3/4 Medium Sand 40-51 inches:7.5YR 3/4 Medium Sand With Loamy Fine Sand Layers And 7.5YR 5/8 & Few 5YR 3/4 Redox |
A. Bottom of distribution media: | 4 Decimal Feet |
B. Periodically saturated soil/bedrock: | 3.3 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 3 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
|
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | brian@midwestsoiltesting.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #4857 (09/18/2019)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 09/20/2019 9:08 AM $41 Flat Fee |
$41.00 | x 1 | $41.00 |
Grand Total | |||
Total | $41.00 | ||
Payment 09/20/2019 | $41.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Brian Humpal - 09/20/2019 9:08 AM 53b94eddc274d0cbaa07194896412285 7bbb4ba4e335206f09099626eff6d390 | |
#1 Compliance Inspection Accepted | Paul O'Neel - 10/08/2019 1:29 PM 67bd1474b5e8493328e010beb713a1f9 616a1b938242964f362d628505a2cf6a |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | 10/04/2019: I question the location of soil boring in relation to the STA. Emailed inspector 10-07-19. PMO 10-07-2019: Spoke with Chris from Inspect MN & Midwest Soil Testing at 12p.m. Chris will make changes to inspection report to reflect reason SSTS failed. There is no house on property. Unknown as to what happen to structure (fire, torn down). PMO 10-08-2019: Brian Humpal emailed revised compliance inspection report. Added to file. PMO |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Paul O'Neel | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: |
Certificate of Compliance: |
Letter of Non-Compliance: |