SSTS Permitting
Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2765, Submission # Submission-2021-2963, UID # 35432
Status: System Replaced
Status: System Replaced
System Status
System status on date: | 08/03/2021 | System Status: | Noncompliant |
System - Noncompliant
Reason(s) for noncompliance: | Soil Separation (Compliance Component #4) - Failing to protect groundwater |
Property Information
Property Information: | |||||||||||||||||
Owner's representative: |
|
Impact on Public Health
System discharges sewage to the ground surface: |
No | System discharges sewage to drain tile or surface waters: |
No | System causes sewage backup into dwelling or establishment: |
No |
Verification method(s): | Searched for seeping in yard/backup into home Homeowner testimony (See Comments/Explanation) |
Tank Integrity
System consists of seepage pit, cesspool, drywell, or leaching pit: |
No |
Sewage tank(s) leak below their designed operating depth: |
No |
Verification method(s): | Examined empty (pumped) tank(s) |
Other Compliance Conditions
Maintenance hole covers are damaged, cracked, unsecured, or appear to be structurally unsound: |
No |
Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety: |
No |
System is non protective of groundwater for other conditions as determined by the inspector: |
Yes |
Explain: | Soil Separation only |
Date of Install
Date of install known: | Yes |
Date of installation: | 09/25/1980 |
Soil Separation
Shoreland/Wellhead Protection/Food, beverage, lodging? | No |
Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock: |
No |
Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock.: |
No |
Verification method(s): | Conducted soil observation(s) (Attach boring logs) |
A. Bottom of distribution media: | 2.75 Decimal Feet |
B. Periodically saturated soil/bedrock: | 1 Decimal Feet |
C. System separation: | 0 Decimal Feet |
D. Required compliance separation: | 2 Decimal Feet |
Operating Permit and Nitrogen BMP
Is system operating under an Operating Permit: | No |
Is the system required to employ Nitrogen BMP: | No |
Comments and File Attachments
Attach Files: |
Certification
Inspector: |
Please search for and choose SELF/OTHER if what you need does not appear in the list
|
Inspector Email Address: | mjlcontract@gmail.com |
Terms
Certification
By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
maintenance, or future water usage
Invoice #7174 (08/05/2021)
Charge | Cost | Quantity | Total |
---|---|---|---|
added 08/05/2021 3:55 PM $47 Flat Fee |
$42.00 | x 1 | $42.00 |
Grand Total | |||
Total | $42.00 | ||
Payment 08/05/2021 | $42.00 | ||
Due | $0.00 |
Action: Print
Approvals
Approval | Signature | Options |
---|---|---|
Applicant | Danielle Lang - 08/05/2021 3:56 PM cef05d789f17d46d424c8b623692299a 1d68360fe644386438f9a2abe5769a68 | |
#1 Compliance Inspection Accepted | Sarah Borrell - 09/03/2021 6:19 AM 9ddfe7179932e6df08f0ac12eb844d60 5e65e15610a5c1c987d0ef7d1481ac48 |
Inspection has been approved. All signatures have been obtained.
Text: | |
File(s): |
Text: | Jerry (realtor for seller) called in receipt of NON letter. Wanted to make sure the contracting company submitted the paperwork to replace the ST. Yes. left VM on 9/17/2021. |
File(s): |
Compliance Letter Type: | Failed System, Notice and Order to Comply, Separation | Who's signature should be on the letter? | Sarah Borrell | Permit number to reference in "No Replace" letter: | |
Was the letter sent? | Yes | Compliant/Non-Compliant: | Noncompliant |
Certificate of Compliance: |
Letter of Non-Compliance: |