Compliance Inspection Compliance Inspection Compliance Inspection # CI-2021-2931, Submission # Submission-2021-3135, UID # 37886
Status: Compliance Inspection Accepted
 

System Status

System status on date: 11/24/2021 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
270292023000415210 15TH ST N, TOWN OF WEST LAKELAND1521015THSTNSTILLWATERTOWN OF WEST LAKELAND55082WILLIAMS MEGHAN & NICHOLAS21WEST LAKELAND WOODS 2ND ADD1993
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined Tank Integrity Form (Attach)
Comments/Explanation:
While not a compliance criteria, it should be noted that a deck footing was built over the septic tank. The tank was at normal operating level and no obvious signs of any damage to the tank were observed.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 09/16/1992

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? No
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 2 Decimal Feet
B. Periodically saturated soil/bedrock: 4.5 Decimal Feet
C. System separation: 2.5 Decimal Feet
D. Required compliance separation: 2 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #7599 (11/24/2021)

Charge Cost Quantity Total
Non-Taxable
added 11/24/2021 1:25 PM

$47 Flat Fee

$42.00 x 1 $42.00
Grand Total
Total $42.00
Payment 11/24/2021$42.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 11/24/2021 1:25 PM
541a9206eb750d13637c38029b2b7556
d1256a72704d611e525d7ea8dc1657d7
 
#1 Compliance Inspection AcceptedSarah Borrell - 12/08/2021 11:09 AM
e15f987be1f03a23e8137100193104a8
3608d3e963da3cfa650f7fb4467c5dbc
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Certificate of Compliance Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Compliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by