Compliance Inspection Compliance Inspection Compliance Inspection # CI-2016-0302, Submission # Submission-2016-0349, UID # 4267
Status: Compliance Inspection Accepted
 

System Status

System status on date: 07/22/2016 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
080322011000112100 228TH ST N, CITY OF SCANDIA12100228THSTNSCANDIACITY OF SCANDIA55073DAVID J REICH REV TRS2006
Owner's representative:
Name:
Carly Evans
Phone:
(651327 - 2377
Email:
noemail@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
Tanks pumped 7/21/2016 by Bergersons

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 01/01/2006

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 101.8 Decimal Feet
B. Periodically saturated soil/bedrock: 99 Decimal Feet
C. System separation: 2.8 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Zierke Soil Testing, LLCL119651-249-134628587 Jeffrey Ave Chisago City, MN 55013NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: benzierke@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #1194 (08/04/2016)

Charge Cost Quantity Total
Non-Taxable
added 08/04/2016 8:17 AM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 08/04/2016$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBenjamin J. Zierke - 08/04/2016 8:17 AM
128c03a75c3e33b0e170859c51a4419c
91af0f75617716ed689951ff613362ae
 
#1 Compliance Inspection AcceptedKati Hallermann - 08/05/2016 3:58 PM
a8d4bcafb0929661f85f5ed1687a4da3
5f211d6f17b61de5f30d8ea78a32b9fb
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Who's signature should be on the letter? Permit number to reference in "No Replace" letter:
      Was the letter sent? Compliant/Non-Compliant:
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by