Compliance Inspection Compliance Inspection Compliance Inspection # CI-2023-3636, Submission # Submission-2023-3856, UID # 47836
Status: Compliance Inspection Accepted
 

System Status

System status on date: 08/11/2023 System Status: Compliant

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
020292042000116 POINT RD, CITY OF BAYPORT16POINTRDBAYPORTCITY OF BAYPORT55003CHMIELESKI DEBRA & PATRICK16POINT ADD1934
Owner's representative:
Name:
Tom Trooien
Phone:
(651439 - 7323
Email:
tomtrooien@aol.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Excessive ponding in soil system/D-boxes

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Examined construction records
Examined empty (pumped) tank(s)
Comments/Explanation:
The tanks were at normal operating level, then were pumped & back flushed through the maintenance holes. Lowered a light & camera into the empty tanks - bottoms, walls, covers, risers & maintenance hole covers ok. Although not a compliance criteria, the outlet baffle on the 2nd tank is missing - recommend repairing or replacing. Also recommend extending the riser & cover to grade on the 1st tank.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 06/13/2000

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
Yes
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 1.8 Decimal Feet
B. Periodically saturated soil/bedrock: 4.9 Decimal Feet
C. System separation: 3.1 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
All State Septic ServicesL1568651-439-732312155 Norell Ave N Stillwater, MN 55082NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: tomtrooien@aol.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #9434 (08/11/2023)

Charge Cost Quantity Total
Non-Taxable
added 08/11/2023 3:44 PM

$47 Flat Fee

$45.00 x 1 $45.00
Grand Total
Total $45.00
Payment 08/11/2023$45.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantTom Trooien - 08/11/2023 3:44 PM
e7e4b2e61987812c32db982673dc316b
5f7be11618b1de65866abc351cf5e8f6
 
#1 Compliance Inspection AcceptedSarah Borrell - 09/27/2023 10:21 AM
bf14d6a6575d65becdea9e57ba997fdd
b742fd05bf9c1d26beccd90f8aa5c5ed
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Certificate of Compliance Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Compliant
      Certificate of Compliance:
        Letter of Non-Compliance: