Compliance Inspection Compliance Inspection Compliance Inspection # CI-2017-0717, Submission # Submission-2017-0756, UID # 8747
Status: System Replaced
 

System Status

System status on date: 05/12/2017 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
330322043000313030 182ND ST N, CITY OF SCANDIA13030182NDSTNMARINE ON ST CROIXCITY OF SCANDIA55047JEROME MARY K & SHELLEY L KENDRICK4BIG LAKE VIEW 2ND ADD1976
Owner's representative:
Name:
Gary Olson
Phone:
(651587 - 5059
Email:
gjolson68@gmail.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for surface outlet
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Other methods not listed (See Comments/Explanation)
Comments/Explanation:
See attached report.

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
No

Date of Install

Date of install known: Yes
Date of installation: 01/01/1976

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a two-foot vertical separation
distance from periodically saturated soil or bedrock:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 96.8 Decimal Feet
B. Periodically saturated soil/bedrock: 99.3 Decimal Feet
C. System separation: -2.5 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Attach Files:

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
Zierke Soil Testing, LLCL119651-249-134628587 Jeffrey Ave Chisago City, MN 55013NoNoNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Email Address: benzierke@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #2096 (05/22/2017)

Charge Cost Quantity Total
Non-Taxable
added 05/22/2017 11:11 PM

$40 Flat Fee

$40.00 x 1 $40.00
Grand Total
Total $40.00
Payment 05/22/2017$40.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantBenjamin J. Zierke - 05/22/2017 11:11 PM
a22ef4f4bfc674e3836fad1397e937c2
ad47a32cbd94cba8ef21df04013b9297
 
#1 Compliance Inspection AcceptedChristopher W. LeClair REHS - 06/06/2017 9:16 AM
679a5b575fb408f5e559903b4829ad53
4e1a51a5595b5d2765353fc3f908f383
 
Inspection has been approved. All signatures have been obtained.