Compliance Inspection Compliance Inspection Compliance Inspection # CI-2024-3801, Submission # Submission-2024-4031, UID # 51292
Status: System Replaced
 

System Status

System status on date: 01/29/2024 System Status: Noncompliant

System - Noncompliant

Reason(s) for noncompliance:
Soil Separation (Compliance Component #4) - Failing to protect groundwater

Property Information

Property Information:
Compliance StatusProperty RecordProperty AddressProperty OwnerProperty Attributes
Compliance ExpirationCompliance StatusParent GeoCodePINSite AddressBuilding NumberStreet NameTypeDirCityMunicipalityzipOwnerLotBlockPlat Year BuiltProperty Hold
360312143000411960 JULY AVE N, CITY OF HUGO11960JULYAVENHUGOCITY OF HUGO55038BRYANT LEANNE M1998
Property Owner's Mailing Address
(if different than property address):
11960 July Ave
Hugo MN 55038
Owner's representative:
Name:
Nate Alm
Phone:
(651248 - 7678
Email:
natea@frattalonecompanies.com

Impact on Public Health

System discharges sewage to
the ground surface:
No System discharges sewage to
drain tile or surface waters:
No System causes sewage backup
into dwelling or establishment:
No
Verification method(s):
Searched for seeping in yard/backup into home
Homeowner testimony (See Comments/Explanation)

Tank Integrity

System consists of seepage pit,
cesspool, drywell, or leaching pit:
No
Sewage tank(s) leak below their
designed operating depth:
No
Verification method(s):
Probed tank(s) bottom

Other Compliance Conditions

Maintenance hole covers are damaged, cracked,
unsecured, or appear to be structurally unsound:
No
Other issues (electrical hazards, etc.) to
immediately and adversely impact public
health or safety:
No
System is non protective of groundwater for other
conditions as determined by the inspector:
Yes
Explain:
Soil seperation

Date of Install

Date of install known: No

Soil Separation

Shoreland/Wellhead Protection/Food, beverage, lodging? Yes
Drainfield has at least a three-foot vertical separation
distance from periodically saturated soil or bedrock.:
No
Drainfield meets the designed vertical separation
distance from periodically saturated soil or bedrock.:
No
Verification method(s):
Conducted soil observation(s) (Attach boring logs)
A. Bottom of distribution media: 2.5 Decimal Feet
B. Periodically saturated soil/bedrock: 1 Decimal Feet
C. System separation: 0 Decimal Feet
D. Required compliance separation: 3 Decimal Feet

Operating Permit and Nitrogen BMP

Is system operating under an Operating Permit: No
Is the system required to employ Nitrogen BMP: No

Comments and File Attachments

Certification

Inspector:
NameLicense NumberPhone NumberAddressMaintainerInstallerService ProviderDesignerInspector
MJL Contracting IncL2449763-444-66685265 269th Ave NE Isanti, MN 55040YesYesNoYesYes
Please search for and choose SELF/OTHER if what you need does not appear in the list
Inspector Contact (If 'self/other' is selected from the Inspector Lookup): Danielle Lang
Inspector Email Address: mjlcontract@gmail.com

Terms

Certification
  • By submitting this form I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of the future
    system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate
    maintenance, or future water usage

Invoice #9873 (01/29/2024)

Charge Cost Quantity Total
Non-Taxable
added 01/29/2024 2:25 PM

$47 Flat Fee

$46.00 x 1 $46.00
Grand Total
Total $46.00
Payment 01/29/2024$46.00
Due$0.00
Action: Print  

Approvals

ApprovalSignatureOptions
ApplicantDanielle Lang - 01/29/2024 2:25 PM
4cf43cbbb430c355dc28b4031ede1005
f6958654db5407d40e3af60641f0edbc
 
#1 Compliance Inspection AcceptedSarah Borrell - 01/31/2024 12:47 PM
e15b7ce915a0d1000dc2b4f0ea8caa8f
29b234d980c94179c342dcdc1dc46af1
 
Inspection has been approved. All signatures have been obtained.
Text:
File(s):
    Text:
    File(s):
      Compliance Letter Type: Failed System, Notice and Order to Comply, Separation Who's signature should be on the letter? Sarah Borrell Permit number to reference in "No Replace" letter:
      Was the letter sent? Yes Compliant/Non-Compliant: Noncompliant
      Certificate of Compliance:
        Letter of Non-Compliance:
          Powered by